09/03
2-669
DC 3535/2240/1632, WC M24
116-376, 116-377
Status Indicator RAPs
Initial issue
116-376 Port 9100 Software
[Port 9100 Software Fail
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).
116-377 Video DMA
[Video DMA failure was detected.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).