09/03
2-375
DC 3535/2240/1632, WC M24
16-786, 16-787
Status Indicator RAPs
Initial issue
16-786 HDD Scan Write
Internal HDD Write Error at Scanning. A temporary file cannot be written to the internal HDD at
the Scan to Server file transfer.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
HDD may be filled with print jobs. Allow time and retry.
If the problem continues, format the HDD (ADJ 9.8).
If the problem continues, replace the HDD (PL 13.1).
16-787 Job Template Syntax
This is a syntax error in the Job Template during Scan to Server operation and limited to the
following cases (because of Redirector detection): Server IP Address Incorrect (IP Syntax
Error)
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Check the contents of the attributes (string RepositoryName) in the Job Template file.