09/03
6-128
DC 3535/2240/1632, WC M24
GP 5, GP 6
Initial issue
General Procedures and Information
GP 6 Resetting the Administrator Password
Purpose
The purpose of this procedure is to allow the CSE to recover the Administrator Password in sit-
uations where the customer has changed the password from the default value, and subse-
quently lost or forgotten the password.
Procedure
1. Enter UI Diagnostic Mode.
2. Press the Access button on the Control Panel
3. On the display, select System Settings, then Common Settings, then Diagnostics.
4. Select NVM Read/Write.
5. Enter location 700-171 and press Confirm/Change. This is the current password. You
can provide this number to the customer, or set the location to the default value (11111)
and allow the customer to enter a new number from Tools mode.
150 V.34 Signal Output 24000/3429 (HDLC Flag)
151 V.34 Signal Output 26400/3429 (HDLC Flag)
152 V.34 Signal Output 28800/3429 (HDLC Flag)
153 V.34 Signal Output 31200/3429 (HDLC Flag)
154 V.34 Signal Output 33600/3429 (HDLC Flag)
160 DTMF Signal Output Signal Tone 697Hz
161 DTMF Signal Output Signal Tone 770Hz
162 DTMF Signal Output Signal Tone 852Hz
163 DTMF Signal Output Signal Tone 941Hz
164 DTMF Signal Output Signal Tone 1209Hz
165 DTMF Signal Output Signal Tone 1336Hz
166 DTMF Signal Output Signal Tone 1477Hz
167 DTMF Signal Output Signal Tone 1633Hz
Table 1 Fax Diagnostic signal numbers
Signal No. Output Description