09/03
2-371
DC 3535/2240/1632, WC M24
16-778, 16-779
Status Indicator RAPs
Initial issue
16-778 HDD Capacity
The insufficient HDD capacity was detected during scanned image conversion process by I-
Formatter.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Check HDD (PL 13.1) harness connections and retry scanning.
16-779 Scan Image Conversion
An error has occurred due to other causes than HDD Access during scanned image conver-
sion process by I-Formatter.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Again, switch power off then on and perform the operation again.