09/03
2-665
DC 3535/2240/1632, WC M24
116-366, 116-367
Status Indicator RAPs
Initial issue
116-366 Report Generator Software
An operation failure of the Report Generator. Due to an error during the software processing,
the subsequent processes cannot be performed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).
116-367 Parallel I/F Software
Overall fatal errors of the Parallel/F. Due to an error during the software processing, the subse-
quent processes cannot be performed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).