09/03
2-664
DC 3535/2240/1632, WC M24
116-361, 116-365
Initial issue
Status Indicator RAPs
116-361 Spool Fatal HD
Fatal error of the SPL HD
The spool Cont detected an error at HDD access.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Run the HDD Diag (dC355).
Replace the HDD (PL 13.1).
If the problem continues, replace the ESS PWB (PL 13.1).
116-365 Spool Fatal
Fatal error of the SPL
Due to an error during the software processing, the subsequent processes cannot be per-
formed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).