09/03
6-100
DC 3535/2240/1632, WC M24
850-xxx ESS Foreign Interface NVM List
Initial issue
General Procedures and Information
850-xxx ESS Foreign Interface NVM List
Table 1 Chain 840
Chain/Link Name Default Range Description
850-001 Foreign Interface Enable 0 0~1 0 = Enable; 1 = Disable
850-009 Print Control Feature Enable 1 0~1 0=No Control; 1=Control
850-010 Interrupt Enable when Subtractive
device connected
0 0~1 0 = Enable; 1 = Disable
850-015 Scan Control Feature Enable 0 0~1 0=No Control; 1=Control
850-016 “Disable” behavior when Subtractive
device connected
0 0~1 0=Job Cancel; 1=Job Pause