09/03
6-33
DC 3535/2240/1632, WC M24
744--xxx Fuser NVM List
General Procedures and Information
Initial issue
744-239
DC3535 only
Applied Time for 104mm/sec. OHP Skip
modeTarget Run Temp.(T[Run#4])
6 1~100 (1 bit=5 sec.)
744-239
DC3535 only
Applied Time for 104mm/sec. OHP Skip
modeTarget Run Temp.(T[Run#5])
16 1~100 (1 bit=5 sec.)
744-248 Condensation Guard Mode 0 0~10 Wait time from Fuser ready (1 count=1 min.)
744-249
DC3535 only
STS-1 Ready temperature #2 145 100~150 STS-1 Ready temperature for STS-1, 2 - temperature value of 744-253 or lower at recovery from Low-Power/
Sleep mode (1 bit=1 deg.C)
744-250
DC3535 only
STS-2 Ready temperature #2 145 100~150 STS-2 Ready temperature for STS-1, 2 - temperature value of 744-253 or lower at recovery from Low-Power/
Sleep mode (1 bit=1 deg.C)
744-251
DC3535 only
STS-1 Ready temperature #3 145 100~150 STS-1 Ready temperature for STS-1, 2 - temperature value of 744-253 or higher at recovery from Low-Power/
Sleep mode (1 bit=1 deg.C)
744-252
DC3535 only
STS-2 Ready temperature #3 145 100~150 STS-2 Ready temperature for STS-1, 2 - temperature value of 744-253 or higher at recovery from Low-Power/
Sleep mode (1 bit=1 deg.C)
744-253
DC3535 only
Change Ready temperature 45 20~100 Threshold for changing Ready temperature at recovery from Low-Power/Sleep mode
Table 1 Chain 744
Chain-Link Name Default Range Description