09/03
2-506
DC 3535/2240/1632, WC M24
83-746, 83-747
Initial issue
Status Indicator RAPs
83-746 Dial Tone Error
One of the following has occurred:
• Dial tone cannot be detected before dialing. DT1 cannot be detected.
• Busy tone is detected before dialing. BT1 detected.
• Busy tone is detected before dialing. BT2 detected.
• Congestion tone is detected before dialing. Switch board busy. CT1 detected.
• Congestion tone is detected before dialing. Switch board busy. CT2 detected.
• Dial tone cannot be detected during dialing. DT1 cannot be detected. May occur when
outside line is used by dialing 0 from PBX.
• Busy tone is detected during dialing. BT1 detected.
• Busy tone is detected during dialing. BT2 detected.
• Congestion tone is detected during dialing. Switch board busy. CT1 detected.
• Congestion tone is detected during dialing. Switch board busy. CT2 detected.
• The second dial tone cannot be detected during dialing. DT2 cannot be detected.
• Busy tone is detected after dialing. BT1 detected.
• Busy tone is detected after dialing. BT2 detected.
• Congestion tone is detected after dialing. CT1 detected.
• Congestion tone is detected after dialing. CT2 detected.
Procedure
Switch power off then on. Re-try the Fax job
83-747 Abort Error
Pause during dialing.
Procedure
Switch power off then on. Re-try the Fax job