Status Indicator RAPs
Initial issue
116-319 Serial
There is no serial board at the serial board initialization failure.
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Reinstall the serial board.
116-320 STREAMZ Software
Fatal error of the STREAMZ. Due to an error during the software processing, the subsequent
processes cannot be performed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).