09/03
2-653
DC 3535/2240/1632, WC M24
116-333, 116-335
Status Indicator RAPs
Initial issue
116-333 LocalTalk Software
Due to an error during the software processing, the subsequent processes cannot be per-
formed.
Initial Actions
Switch power off then on. If the problem persists, continue with the procedure.
Procedure
Perform GP 3. If the problem continues, reload system software. If the problem persists,
replace the ESS PWB (PL 13.1).
116-335 MFIO HD
HD failure to be detected by MFIO
Procedure
Switch power off then on. The problem continues.
YN
Return to service call procedures.
Set up the HDD (ADJ 9.8).
If the problem continues, replace the HDD (PL 13.1).
If the problem continues, replace the ESS PWB (PL 13.1).