1-3
Field Description
Link Fault
Indicates whether an Ethernet OAM link error is present: 0 for no and 1
for yes.
Dying Gasp
Indicates whether a fatal error is present: 0 for no and 1 for yes.
Critical Event
Indicates whether a critical error is present: 0 for no and 1 for yes.
Local Evaluating
Indicates whether the local-to-remote configuration negotiation is
complete:
z COMPLETE for completed
z REVERSED for uncompleted
Remote Evaluating
Indicates whether the remote-to-local configuration negotiation is
complete:
z COMPLETE for completed
z REVERSED for uncompleted
Packets statistic
Statistics about Ethernet OAMPDUs sent and received
OAMPDU
Total number of the Ethernet OAMPDUs sent and received
OAMInformation
Number of the Information OAMPDUs sent and received
OAMEventNotification
Number of the Event notification OAMPDUs sent and received
OAMUniqueEventNotification
Number of the unduplicated Event notification OAMPDUs sent or
received uniquely.
OAMDuplicateEventNotification
Number of the duplicate Event notification OAMPDUs sent or received.
# Display the Ethernet OAM information of the peer port Ethernet 1/0/1.
<Sysname> display oam remote interface ethernet 1/0/1
Port : Ethernet1/0/1
Link Status : Up
Information of the latest received OAM packet:
OAMRemoteMACAddress : 00e0-fd73-6502
OAMRemotePDUConfiguration : 1500
OAMRemoteState :
--------------------------------------------------------------------------
Remote_mux_action : FWD Remote_par_action : FWD
OAMRemoteConfiguration :
--------------------------------------------------------------------------
OAM Mode : Active Unidirectional Support : YES
Loopback Support : YES Link Events : YES
Variable Retrieval : NO
OAMRemoteFlagsField :
--------------------------------------------------------------------------
Link Fault : 0 Dying Gasp : 0
Critical Event : 0 Local Evaluating : COMPLETE
Remote Evaluating : COMPLETE