EasyManuals Logo

ST STM32L0x3 User Manual

ST STM32L0x3
1043 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #505 background imageLoading...
Page #505 background image
RM0367 Rev 7 505/1043
RM0367 General-purpose timers (TIM2/TIM3)
546
Downcounting configuration
Downcounting is active when DIR bit in TIMx_CR1 register is high. Refer to Section :
Downcounting mode on page 486.
In PWM mode 1, the reference signal OCxREF is low as long as TIMx_CNT>TIMx_CCRx
else it becomes high. If the compare value in TIMx_CCRx is greater than the auto-reload
value in TIMx_ARR, then OCxREF is held at ‘1. 0% PWM is not possible in this mode.
PWM center-aligned mode
Center-aligned mode is active when the CMS bits in TIMx_CR1 register are different from
‘00 (all the remaining configurations having the same effect on the OCxREF/OCx signals).
The compare flag is set when the counter counts up, when it counts down or both when it
counts up and down depending on the CMS bits configuration. The direction bit (DIR) in the
TIMx_CR1 register is updated by hardware and must not be changed by software. Refer to
Section : Center-aligned mode (up/down counting) on page 489.
Figure 137 shows some center-aligned PWM waveforms in an example where:
TIMx_ARR=8,
PWM mode is the PWM mode 1,
The flag is set when the counter counts down corresponding to the center-aligned
mode 1 selected for CMS=01 in TIMx_CR1 register.
For code example, refer to A.11.9: Center-aligned PWM configuration example.