09/03
6-29
DC 3535/2240/1632, WC M24
742--xxx Paper Handling NVM List
General Procedures and Information
Initial issue
742-110 Pre-T/A Start Timing TTM-Tray 4 (Half) 37 0~58 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (431~931 msec.) (1bit=4.8924 msec.)
742-111 Main Feed Start Timing 3TM-Tray 2
(Half)
10 0~22 Sets time between Main Feed Start and Pre-T/A (330~830 msec.). (1bit=4.8924 msec.)
742-112 Main Feed Start Timing 3TM-Tray 3
(Half)
10 0~22 Sets time between Main Feed Start and Pre-T/A (570~1070 msec.). (1bit=4.8924 msec.)
742-113 Main Feed Start Timing 3TM-Tray 4
(Half)
10 0~22 Sets time between Main Feed Start and Pre-T/A (810~1310 msec.) (1bit=4.8924 msec.)
742-114 Main Feed Start Timing TTM-Tray 3
(Half)
10 0~22 Sets time between Main Feed Start and Pre-T/A (780~1280 msec.) (1bit=4.8924 msec.)
742-115 Main Feed Start Timing TTM-Tray 4
(Half)
10 0~22 Sets time between Main Feed Start and Pre-T/A (1410~1910 msec.) (1bit=4.8924 msec.)
742-116 Tray Type selection XC=1;
XE=0
0~2 Set Tray Type to appropriate mkt setting: 0=metric; 1=inch; 2=FX K-size
742-118
DC3535 only
Regi Loop Length Adjust
(Tray 5 Long Document)(104mm/sec.)
9 0~81 2.4462 msec/bit
742-120
DC3535 only
Adjust Lead Regi (104mm/sec.)
(Heavy1)
22 0~40 Lead Regi adjustment (Heavy1) at 104mm/sec. (0.2544mm/bit)
742-121
DC3535 only
Adjust Lead Regi (104mm/sec.)
(Heavy1)
23 0~40 Lead Regi adjustment (Heavy1) from Tray 5 at 104mm/sec. (0.2544mm/bit)
742-122
DC3535 only
Adjust Lead Regi (104mm/sec.)
(Heavy1)
22 0~40 Lead Regi adjustment (Heavy1) from Duplex at 104mm/sec. (0.2544mm/bit)
742-123
DC3535 only
RegiLoop Length Adjust (Duplex
Heavy1) (104mm/sec., 2-sheet feed)
39 0~81 RegiLoop adjustment(104mm/sec.) Heavy1 from Dup (Feed length: Letter LEF or smaller) (1bit=2.4462 msec.)
742-124
DC3535 only
RegiLoop Length Adjust (Duplex
Heavy1) (104mm/sec., 1-sheet feed)
35 0~81 RegiLoop adjustment(104mm/sec.) Heavy1 from Dup (Feed length exceeding LetterLEF)
Regi Sensor On - DUP MOT Step Down start: 86.66msec
742-125
DC3535 only
T/A Motor2 Off Timing 53 33~73 T/A Motor Stop timing at TTM #4T/A Roll Pre Feed (10 msec/bit)
742-126
DC3535 only
T/A Motor2 Start Timing 110 90~130 T/A Motor Start timing at TTM #4T/A Roll Pre Feed (10 msec/bit)
742-127
DC3535 only
T/A Motor Off Acceptance 48 28~68 TTM #4T/A Roll Pre Feed implementation reject/accept (10 msec/bit)
742-128
DC3535 only
Feed Roller Warning 298500 0~1500000 Tray Feed Roller Warning display timing (number of feeds)
742-129
DC3535 only
Adjust Lead Regi (52mm/sec.)
(Heavy2)
20 0~40 Lead Regi adjustment (52mm/sec.) from Tray (Heavy2) (0.2544mm/bit)
742-130
DC3535 only
Adjust Lead Regi (52mm/sec.)
(Heavy2)
41 0~81 RegiLoop adjustment (52mm/sec.) from Tray (Heavy2) (5.025msec/bit)
Table 1 Chain 742
Chain-Link Name Default Range Description