09/03
6-28
DC 3535/2240/1632, WC M24
742--xxx Paper Handling NVM List
Initial issue
General Procedures and Information
742-094
DC3535
Pre-T/A Start Timing 3TM-Tray 3 118 0~183 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (365~865 msec.) (1bit=1.5418 msec.)
742-095
DC2240/1632
Pre-T/A Start Timing 3TM-Tray 4 139 0~215 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (429~929 msec.) (1bit=1.31136 msec.)
742-095
DC3535
Pre-T/A Start Timing 3TM-Tray 4 118 0~183 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (429~929 msec.) (1bit=1.5418 msec.)
742-096
DC2240/1632
Pre-T/A Start Timing TTM-Tray 3 139 0~215 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (457~957 msec.) (1bit=1.31136 msec.)
742-096
DC3535
Pre-T/A Start Timing TTM-Tray 3 118 0~183 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (457~957 msec.) (1bit=1.5418 msec.)
742-097
DC2240/1632
Pre-T/A Start Timing TTM-Tray 4 139 0~215 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (431~931 msec.) (1bit=1.31136 msec.)
742-097
DC3535
Pre-T/A Start Timing TTM-Tray 4 118 0~183 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (431~931 msec.) (1bit=1.5418 msec.)
742-098
DC2240/1632
Main Feed Start Timing 3TM-Tray 2 38 0~83 Sets time between Main Feed Start and Pre-T/A (330~830 msec.). (1bit=1.31136 msec.)
742-098
DC3535
Main Feed Start Timing 3TM-Tray 2 32 0~71 Sets time between Main Feed Start and Pre-T/A (330~830 msec.). (1bit=1.5418 msec.)
742-099
DC2240/1632
Main Feed Start Timing 3TM-Tray 3 38 0~83 Sets time between Main Feed Start and Pre-T/A (570~1070 msec.). (1bit=1.31136 msec.)
742-099
DC3535
Main Feed Start Timing 3TM-Tray 3 32 0~71 Sets time between Main Feed Start and Pre-T/A (570~1070 msec.). (1bit=1.5418 msec.)
742-100
DC2240/1632
Main Feed Start Timing 3TM-Tray 4 38 0~83 Sets time between Main Feed Start and Pre-T/A (810~1310 msec.). (1bit=1.31136 msec.)
742-100
DC3535
Main Feed Start Timing 3TM-Tray 4 32 0~71 Sets time between Main Feed Start and Pre-T/A (810~1310 msec.). (1bit=1.5418 msec.)
742-101
DC2240/1632
Main Feed Start Timing TTM-Tray 3 38 0~83 Sets time between Main Feed Start and Pre-T/A (780~1280 msec.). (1bit=1.31136 msec.)
742-101
DC3535
Main Feed Start Timing TTM-Tray 3 32 0~71 Sets time between Main Feed Start and Pre-T/A (780~1280 msec.). (1bit=1.5418 msec.)
742-102
DC2240/1632
Main Feed Start Timing TTM-Tray 4 38 0~83 Sets time between Main Feed Start and Pre-T/A (1410~1910 msec.). (1bit=1.31136 msec.)
742-102
DC3535
Main Feed Start Timing TTM-Tray 4 32 0~71 Sets time between Main Feed Start and Pre-T/A (1410~1910 msec.). (1bit=1.5418 msec.)
742-103 Select Metric or Inch (Tray 5 Auto
Detect)
XC=1;
XE=00
0~1 0=metric (A/B) paper; 1=Inch-sized paper
742-104 Select 2ndBTR Cleaning (Tray 5 Auto
Detect)
1 0~1 0=No; 1=Yes
742-105 RegiLoop Length Adjust (DUP) 35 0~79 Lead Regi Length Adjustment (P Speed) from Dup (Feeding Length Letter-LEF and longer)Default=157ms
(1bit=2.4462 msec.)
742-106 Pre-T/A Start Timing 3TM-Tray 2 (Half) 37 0~58 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (303~803 msec.) (1bit=4.8924 msec.)
742-107 Pre-T/A Start Timing 3TM-Tray 3 (Half) 37 0~58 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (365~865 msec.) (1bit=4.8924 msec.)
742-108 Pre-T/A Start Timing 3TM-Tray 4 (Half) 37 0~58 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (429~929 msec.) (1bit=4.8924 msec.)
742-109 Pre-T/A Start Timing TTM-Tray 3 (Half) 37 0~58 Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (457~957 msec.) (1bit=4.8924 msec.)