09/03
6-41
DC 3535/2240/1632, WC M24
747--xxx Transfer NVM List
General Procedures and Information
Initial issue
747-462 High speed 1st Transfer B/W K ECC #4 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-029)x 1.0
747-463 High speed 1st Transfer B/W K ECC #5 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-029)x 1.0
747-464 High speed 1st Transfer B/W K ECC #6 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-029)x 1.0
747-465 High speed 1st Transfer B/W K ECC #7 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-029)x 1.0
747-466 High speed 1st Transfer B/W K ECC #8 1140 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-029)x 1.0
747-467 High speed 1st Transfer B/W K ECC #9 1140 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-029)x 1.0
747-468 Normal speed 1st Transfer B/W K ECC #1 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-030)x 1.0
747-469 Normal speed 1st Transfer B/W K ECC #2 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-030)x 1.0
747-470 Normal speed 1st Transfer B/W K ECC #3 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-030)x 1.0
747-471 Normal speed 1st Transfer B/W K ECC #4 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-030)x 1.0
747-472 Normal speed 1st Transfer B/W K ECC #5 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-030)x 1.0
747-473 Normal speed 1st Transfer B/W K ECC #6 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-030)x 1.0
747-474 Normal speed 1st Transfer B/W K ECC #7 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-030)x 1.0
747-475 Normal speed 1st Transfer B/W K ECC #8 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-030)x 1.0
747-476 Normal speed 1st Transfer B/W K ECC #9 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-030)x 1.0
747-477 Low speed 1st Transfer B/W K ECC #1 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
747-478 Low speed 1st Transfer B/W K ECC #2 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
747-479 Low speed 1st Transfer B/W K ECC #3 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
747-480 Low speed 1st Transfer B/W K ECC #4 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
747-481 Low speed 1st Transfer B/W K ECC #5 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
747-482 Low speed 1st Transfer B/W K ECC #6 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
Table 1 Chain 747
Chain-
Link Name Default Range Description