747-483 Low speed 1st Transfer B/W K ECC #7 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
747-484 Low speed 1st Transfer B/W K ECC #8 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
747-485 Low speed 1st Transfer B/W K ECC #9 1000 0~2000 Environment Control Coefficient of 1st transfer output for K
Ex.: In case of 1000: µA=((value in 746-020)+(value in 746-303))x(value in 746-031)x 1.0
Table 1 Chain 747
Chain-
Link Name Default Range Description
Table 1 Chain 751
Chain-Link Name Default Range Description
751-052 BCR Charge Compensate mode (SW) 0 0~3 Charge Correction. 0=Performs Wear & Environment Correction (Default); 1=Disables Charge Correction;
2=Performs Environment Correction Only; 3=Performs Wear Correction Only
751-053
DC2240/1632
BCR VM temperature & humidity com-
pensate mode (SW)
0 0, 1 Vmid Factor Environment Correction. 0=Execute; 1=Disable
751-132 Bottle Full Counter Print (Max Value) 900 0~65535 Max Setup Value of EMP Counter Print (1 Count=1print)
751-133 Bottle Full (Flag) 0 0~2 0=Empty; 1=Near Full; 2=Full
751-134 Bottle Not In Position (Flag) 0 0, 1 Availability of the Toner Waster Bottle (0=Bottle set; 1=No bottle)
751-135 Print Volume (Counter) 0 0~65535 Total count of # of prints (1 Count=1 sheet)
751-136 Bottle Full Counter Dispense (Max
Value)
500 0~65535 Max Setup Value of EMP Counter Dispense (1 Count=1 sec.)
751-137 Dispense Time Count (4Color Counter) 0 0~65535 Total Count of 4 Colors Dispense Time
751-138 Bottle Sns Mode (SW) 0 0~2 Specifies the Count method until Bottle Full. 0=Auto(Print&Dispense); 1=Only # of prints; 2=Only Dispense time
751-159 BCR Cln Trigger (SW) 3 0~3 Selection SW for Trigger types to operate the BCR Cleaner. 0=CV Count; 1=Drum Cycle Count; 2=Pixel Count;
3=PV Count+ Pixel Count+Drum Cycle
751-160 CV Count Total (Counter) 0 0~65535 Each cumulative ERU by Billing Count (1 Count=1pv)
751-161 Drum Cycle Count Total 0 0~65535 cumulative Drum Cycle (1 Count=10cycle)
751-162 Pixel Count Total (Counter) 0 0~10000000 cumulative K pixel count. units of 1 step is based on the ICDC control pixel count (1 Count=1dot/1 gradation)
751-163 BCR Cln CV Count Limit Value (Limiter) 25 0~255 Threshold in operating BCR Cleaner (Operation after reaching this value) (1 Count=100pv)
751-164 BCR Cln Cycle Count Limit Value (Lim-
iter)
50 0~255 Threshold in operating BCR Cleaner (Operation after reaching this value) (1 Count=1k cycle)
751-165 BCR Cln Pixel Count Limit Value (Lim-
iter)
15 0~255 Operating threshold for BCR Cleaner. (1 Count=(1dot/1 gradation)/10K)
751-167 BCR Cleaning Count 0 0~1000 Reads the No. of BCR Cleaner Operations. (1 Count=1 time)
751-168 CRU Type 0 0~255 80 = XC, ESG, DMO value
751-177 P/R Life Warning (Limiter) 1420 0~2000 Warning value of Drum Cartridge (All engine common) (1 bit=0.01µm)
751-178 P/R Life End of Life (Limiter) 1500 0~2000 End of Life value of Drum Cartridge (All engine common) (1 bit=0.01µm)
751-200 #Y_BCR DC corrected VH value 620 0~1023 VH Output Value of #Y Engine after Correction (All Speed common) (1 Count=-1.173V)
751-201 #M_BCR DC corrected VH value 620 0~1023 VH Output Value of #M Engine after Correction (All Speed common) (1 Count=-1.173V)
751-202 #C_BCR DC corrected VH value 620 0~1023 VH Output Value of #C Engine after Correction (All Speed common) (1 Count=-1.173V)