09/03
6-46
DC 3535/2240/1632, WC M24
752-xxx Procon NVM List
Initial issue
General Procedures and Information
752-441 Warn LD light amount Setting [C] 0 0~1 Warning when the Laser Diode light quantity reached Upper or Lower Limit.
752-442 Warn LD light amount Setting [K] 0 0~1 Warning when the Laser Diode light quantity reached Upper or Lower Limit.
752-453 VBias [Y] 887 0~1023 DC VBias value
752-454 VBias [M] 887 0~1023 DC VBias value
752-455 VBias [C] 887 0~1023 DC VBias value
752-456 VBias [K] 887 0~1023 DC VBias value
752-474 Flag Empty Detection Status [Y] 0 0~3 Flag of Empty status (0=Normal 1=In Empty Count 2=Near Empty 3=End)
752-475 Flag Empty Detection Status [M] 0 0~3 Flag of Empty status (0=Normal 1=In Empty Count 2=Near Empty 3=End)
752-476 Flag Empty Detection Status [C] 0 0~3 Flag of Empty status (0=Normal 1=In Empty Count 2=Near Empty 3=End)
752-477 Flag Empty Detection Status [K] 0 0~3 Flag of Empty status (0=Normal 1=In Empty Count 2=Near Empty 3=End)
752-496 Nominal value for NEAR Detection [Y] 625 0~32767 Count threshold for Near Detection
752-497 Nominal value for NEAR Detection [M] 625 0~32767 Count threshold for Near Detection
752-498 Nominal value for NEAR Detection [C] 625 0~32767 Count threshold for Near Detection
752-499 Nominal value for NEAR Detection [K] 625 0~32767 Count threshold for Near Detection
752-683 Disp time Totalizing value [Y] 0 0~4294967295 Total of Disp Motor driving time
752-684 Disp time Totalizing value [M] 0 0~4294967295 Total of Disp Motor driving time
752-685 Disp time Totalizing value [C] 0 0~4294967295 Total of Disp Motor driving time
752-686 Disp time Totalizing value [K] 0 0~4294967295 Total of Disp Motor driving time
752-784 Fail Disp Unusual [Y] 0 0~1 Fail when new Toner Cartridge is installed and the Disp Motor Drive did not shift from new to old.
0=Normal; 1=Error
752-785 Fail Disp Unusual [M] 0 0~1 Fail when new Toner Cartridge is installed and the Disp Motor Drive did not shift from new to old.
0=Normal; 1=Error
752-786 Fail Disp Unusual [C] 0 0~1 Fail when new Toner Cartridge is installed and the Disp Motor Drive did not shift from new to old.
0=Normal 1=Error
752-787 Fail Disp Unusual [K] 0 0~1 Fail when new Toner Cartridge is installed and the Disp Motor Drive did not shift from new to old.
0=Normal 1=Error
752-788 min. PV Threshold 3 0~255 Minimum PV from Near empty to empty (M/Cstop)
752-804 DispTime Totalizing value for age Cor-
rection [Y]
0 0~4294967295 cumulative dispense time for deterioration correction of ATC Control nominal value. Set to 0 at replacement of
Developer.
752-805 DispTime Totalizing value for age Cor-
rection [M]
0 0~4294967295 cumulative dispense time for deterioration correction of ATC Control nominal value. Set to 0 at replacement of
Developer.
752-806 DispTime Totalizing value for age Cor-
rection [C]
0 0~4294967295 cumulative dispense time for deterioration correction of ATC Control nominal value. Set to 0 at replacement of
Developer.
752-807 DispTime Totalizing value for age Cor-
rection [K]
0 0~4294967295 cumulative dispense time for deterioration correction of ATC Control nominal value. Set to 0 at replacement of
Developer.
752-814 Pre Near EMP Factor 80 0~255 Factor correcting [Near Detection Nominal Value] after Pre Near is displayed.
752-864
DC3535 only
Set ATC Control Nominal Value [2][Y] 565 0~1023 ATC Control nominal value before environment/deterioration correction set as center value
752-865
DC3535 only
Set ATC Control Nominal Value [2][M] 565 0~1023 ATC Control nominal value before environment/deterioration correction set as center value
752-866
DC3535 only
Set ATC Control Nominal Value [2][C] 565 0~1023 ATC Control nominal value before environment/deterioration correction set as center value
Table 1 Chain 752