09/03
6-45
DC 3535/2240/1632, WC M24
752-xxx Procon NVM List
General Procedures and Information
Initial issue
752-156 ATC Control Nominal Value [Y] 500 0~1023 [Set ATC Control Nominal Value]+[ATC Environment Correction Value]+[ATC Deterioration Correction
Value]+[ATC Nominal Value offset]
752-157 ATC Control Nominal Value [M] 500 0~1023 [Set ATC Control Nominal Value]+[ATC Environment Correction Value]+[ATC Deterioration Correction
Value]+[ATC Nominal Value offset]
752-158 ATC Control Nominal Value [C] 500 0~1023 [Set ATC Control Nominal Value]+[ATC Environment Correction Value]+[ATC Deterioration Correction
Value]+[ATC Nominal Value offset]
752-159 ATC Control Nominal Value [K] 500 0~1023 [Set ATC Control Nominal Value]+[ATC Environment Correction Value]+[ATC Deterioration Correction
Value]+[ATC Nominal Value offset]
752-162 Temp Average 100 80~200 Temperature average value after converting the temperature sensor output to temperature (80=-20 degree Cel-
sius, 100=0 degree Celsius, 200=100 degree Celsius)
752-163 Humidity Average 0 0~100 Humidity average value after converting the humidity sensor output to humidity
752-176 Fail Environment sensor TEMP 0 0~1 [Detection relation (Temperature/Humidity)] Temperature Sensor Fail (Fixed as [Standard Temperature])
752-177 Fail Environment sensor Humidity 0 0~1 [Detection relation (Temperature/Humidity)] Temperature Sensor Fail (Fixed as [Standard Temperature])
752-324 SW_DispMode 0 0~2 Dispense method changing SW (0=ATC+ICDC, 1=ICDC, 2=Timer Disp)
752-357 Timer Disp time [Y] 5 0~250 Timer Disp Setup Time
752-358 Timer Disp time [M] 5 0~250 Timer Disp Setup Time
752-359 Timer Disp time [C] 5 0~250 Timer Disp Setup Time
752-360 Timer Disp time [K] 5 0~250 Timer Disp Setup Time
752-369 SW Potential Control On/Off 0 0~1 0=Controls Laser Diode light quantity 1=Fixed Laser Diode light quantity
752-371 LD Light qty. (Potential Control=Off) [Y] 300 0~1023 Laser Diode light quantity value when potential control is Off.
752-372 LD Light qty (Potential Control=Off) [M] 300 0~1023 Laser Diode light quantity value when potential control is Off.
752-373 LD Light qty (Potential Control=Off) [C] 300 0~1023 Laser Diode light quantity value when potential control is Off.
752-374 LD Light qty (Potential Control=Off) [K] 300 0~1023 Laser Diode light quantity value when potential control is Off.
752-375 Ideal LD light qty [Y] * 0~1023 Laser Diode light quantity Ideal value calculated from delta-Laser Diode light quantity.
*default=300 for DC2240/1632; 378 for DC3535
752-376 Ideal LD light qty [M] * 0~1023 Laser Diode light quantity ideal value calculated from delta-Laser Diode light quantity.
*default=300 for DC2240/1632; 378 for DC3535
752-377 Ideal LD light qty [C] * 0~1023 Laser Diode light quantity ideal value calculated from delta-Laser Diode light quantity.
*default=300 for DC2240/1632; 378 for DC3535
752-378 Ideal LD light qty [K] * 0~1023 Laser Diode light quantity ideal value calculated from delta-Laser Diode light quantity.
*default=300 for DC2240/1632; 378 for DC3535
752-394 Change in Lim_d_LD Light qty on Job-
start
* 0~1023 Limit of Delta Laser Diode light quantity Feedback at Job Start.
*default=40 for DC2240/1632; 60 for DC3535
752-395 Change in Lim_d_LD Light qty on Job &
Jobend
20 0~1023 Limit of Delta Laser Diode light quantity Feedback at Job End/during Job.
752-396 Change in Lim_d_LD Light qty on Ton-
erRecovery
200 0~1023 Limit of Delta Laser Diode light quantity Feedback at recovery.
752-397 Change in Lim_d_LD Light qty on Job-
start (CL)
* 0~1023 Limit of Delta Laser Diode light quantity Feedback at Job Start (YMC Color differences considered)
*default=40 for DC2240/1632; 60 for DC3535
752-398 Change in Lim_d_LD Light qty on Job &
Jobend (CL)
20 0~1023 Limit of Delta Laser Diode light quantity Feedback at Job End/during Job (YMC Color differences considered)
752-439 Warn LD light amount Setting [Y] 0 0~1 Warning when the Laser Diode light quantity reached Upper or Lower Limit.
752-440 Warn LD light amount Setting [M] 0 0~1 Warning when the Laser Diode light quantity reached Upper or Lower Limit.
Table 1 Chain 752