09/03
6-61
DC 3535/2240/1632, WC M24
760-xxx Regicon NVM List
General Procedures and Information
Initial issue
760-101
DC3535
M-Y margin speed switch variation 138 0~200 (Y margin variation amount when the speed is switched from 104 or 52mm/sec. to 165mm/sec.)-100, for
Magenta
(1 µm/bit)
760-102
DC3535
K-Y margin speed switch variation 83 0~200 (Y margin variation amount when the speed is switched from 104 or 52mm/sec. to 165mm/sec.)-100, for Black
(1 µm/bit)
760-103
DC3535
Skew offset 64 0~70 Difference between the right value and Skew amount detected at the speed of 104mm/sec. (1 µm/bit)
760-104
DC3535
Y-IN-Y margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-105
DC3535
M-IN-Y margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-106
DC3535
K-IN-Y margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-107
DC3535
Y-IN-X margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-108
DC3535
M-IN-X margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-109
DC3535
C-IN-X margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-110
DC3535
K-IN-X margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-111
DC3535
Y-OUT-Y margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-112
DC3535
M-OUT-Y margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-113
DC3535
K-OUT-Y margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-114
DC3535
Y-OUT-X margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-115
DC3535
M-OUT-X margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-116
DC3535
C-OUT-X margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-117
DC3535
K-OUT-X margin MOB reading 0 0~1000 Skew amount + 500µm (1 µm/bit)
760-118
DC3535
Register set value for YSO-ROS at Y
104 & 52mm/s
237 0~474 PS register set value; for debugging
760-119
DC3535
Register set value for YSO-ROS at M
104 & 52mm/s
237 0~474 PS register set value; for debugging
760-120
DC3535
Register set value for YSO-ROS at C
104 & 52mm/s
237 0~474 PS register set value; for debugging
760-121
DC3535
Register set value for YSO-ROS at K
104 & 52mm/s
237 0~474 PS register set value; for debugging
Table 1 Chain 760
Chain-Link Name Default Range Description