09/03
2-154
DC 3535/2240/1632, WC M24
7-954, 7-959
Initial issue
Status Indicator RAPs
7-954 Tray 5 Size Mismatch (Slow Scan Direction)
The paper in the slow scan direction is shorter than the specified paper size.
Procedure
The correct size paper is loaded in the Tray 5.
YN
Load the correct size paper.
Replace the Registration Sensor (PL 2.6).
7-959 Tray 5 Paper Mismatch 1
Incorrect type of transparency detected by the OHP sensor.
Initial Actions
• Ensure that only approved transparencies (no white strip) are used.
• Check that the transparencies are oriented correctly.
• Check for obstructions and clean the OHP Sensor.
Procedure
Open the Left Cover Assembly (PL 2.9). Enter dC330 [008-110] and press Start. Block the
OHP Sensor R (PL 2.6) using a plain sheet of paper. The display changes.
YN
Press Stop. Check the circuit of the OHP Sensor (Figure 1). Refer to the OF 99-1 RAP for
troubleshooting procedure.
Press Stop.
• Ensure that the connectors shown in the circuit diagram (Figure 1) are securely con-
nected and that the wires are not damaged.
• If the problem persists, replace the MCU PWB (PL 13.1).
Figure 1 7-959 RAP Circuit Diagram - OHP Sensor R