09/03
2-238
DC 3535/2240/1632, WC M24
10-421
Initial issue
Status Indicator RAPs
10-421 Fuser End Of Life
Fuser at end of life.
Procedure
The Fuser Assembly was replaced.
YN
Replace the Fuser Assembly (PL 7.2).
Run the dC135 [954-804]. The initial value is 0.
YN
Replace the MCU PWB (PL 13.1).
Ensure that the LIFE setting value is 100K, switch power off then on.
If the problem continues, replace the MCU PWB (PL 13.1).