09/03
2-393
DC 3535/2240/1632, WC M24
17-961, 17-963
Status Indicator RAPs
Initial issue
17-961 Incorrect Transparency Type
Incorrect type of transparency detected by the OHP sensor.
Initial Actions
• Ensure that only approved transparencies (no white strip) are used.
• Check that the transparencies are oriented correctly.
• Check for obstructions and clean the OHP Sensor.
Procedure
Go to the 7-959 RAP.
17-963 Full Stack
The Network Controller reports that the Top Tray is full.
Procedure
Empty the Top Tray. If the problem continues, go to the 7-969 RAP.