EasyManuals Logo

Siemens SIMATIC NET Configuration Manual

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #118 background imageLoading...
Page #118 background image
System time
5.1 System time setting
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
118 Configuration Manual, 10/2015, C79000-G8976-C351-05
The parameters have the following meaning:
Parameter
Description
Range of values / note
name
Name of the entry
maximum 16 characters
begin
Keyword for the start of daylight saving
time.
-
week
Calendar week in a month
1 ... 5
last
Keyword for the last calendar week in a
month
-
weekday
Weekday monday, tuesday, wednesday,
thursday, friday, saturday, sunday
month
Month january, february, march, april,
may, june, july, august, septem-
ber, october, november, decem-
ber
hour
Hour
0 ... 23
end
Keyword for the end of daylight saving
time.
-
Result
The entry for the start and end of daylight saving time was created.
5.1.2.5
no time dst
Description
With this command you delete the entry for the start and end of daylight saving time with the
specified name. If you do not specify a name as the parameter, all entries are deleted.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no time dst [<name(16>]
The parameter has the following meaning:
Parameter
Description
Range of values / note
name
Name of the entry
maximum 16 characters
Result
An entry or the entries for the start and end of daylight saving time was/were deleted.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols