Configuration
3.3 Reset and Defaults
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
81
3.3
Reset and Defaults
This section describes commands for restarting the device and for restoring the original
configuration.
3.3.1
restart
Description
With this command, you restart the device.
Select one of the following configuration settings:
Device restart with the current configuration
Device restart with the factory configuration settings with the exception of the following
parameters:
IP addresses
Subnet mask
IP address of the default gateway
DHCP client ID
DHCP
System name
System location
System contact
User names and passwords
Mode of the device
Device restart with the factory configuration settings.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameters:
restart[{memory|factory}]
The parameters have the following meaning:
if no parameters are specified: restarts the system with the current configuration
Parameter
Description
memory
Resets the system to the factory configuration settings and restarts the system.
The parameters listed above are unaffected by a reset.
factory
Resets the system to the factory configuration settings and restarts the system.
Result
The device is restarted with the selected settings.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals