Security and authentication
10.2 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
391
10.2.2
Commands in the WLAN configuration mode
This section describes commands that you can call up in the WLAN configuration mode.
In the Global Configuration mode, enter the
wlan command to change to this mode.
Commands relating to other topics that can be called in the WLAN configuration mode can
be found in the relevant sections.
If you exit the WLAN configuration mode with the
exitcommand, you return to the Global
configuration mode.
If you exit the WLAN Configuration mode with the
end command, you return to the
Privileged EXEC mode.
10.2.2.1
wlan security ap-radius-authenticator
Description
With this command, you enable the RADIUS server.
Note
This command is available only in access point mode.
Requirement
You are in the WLAN Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-wlan)#
Syntax
Call up the command with the following parameters:
wlan security ap-radius-authenticator <index (1-2)>
The parameter has the following meaning:
Parameters
Description
Range of values / note
index
Index of the RADIUS server
1...2
Result
The RADIUS server is enabled.
Further notes
You disable the RADIUS server with the no wlan security ap-radius-authenticator
command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals