Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
195
6.1.5.44
wlan frequency band (access point)
Description
With this command, you specify the frequency band for the WLAN interface.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan frequency band { 2.4 | 5 }
The parameters have the following meaning:
Parameter
Description
Range of values/note
2.4
Frequency band 2.4 GHz
Default setting: WLAN1: 2.4 GHz
5
Frequency band 5.2 (4.9; 5.6; 5.8) GHz
Result
The frequency band for the WLAN interface is specified.
Further notes
You display the setting with the show wlan basic <wlan 0/X> command.