Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
200 Configuration Manual, 10/2015, C79000-G8976-C351-05
Using the show wlan basic command, check whether or not the current WLAN settings
violate the permitted transmit power restrictions (
TX Power Check) of the selected country.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan max tx-power <dBm(5-20)>
The parameter has the following meaning:
Parameters
Description
Range of values / note
dBm
Transmit power in decibel-milliwatts (dBm) 5...20
Default: 20
Result
The transmit power is specified.
Further notes
You display the setting with the show wlan basic <wlan 0/X> command.
6.1.5.50
wlan mode (access point)
Description
With this command, you specify the transmission standard.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#