Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
280 Configuration Manual, 10/2015, C79000-G8976-C351-05
Result
The MST region is assigned a revision number.
Further notes
You delete a revision number with the no revision command.
You display this setting and other information with the
show spanning tree mst
configuration
command.
6.3.5.6
no revision
Description
With this command, you reset the revision number of the MST region to the default value.
The default value is 0.
Requirement
You are in the MSTP Configuration mode.
The command prompt is as follows:
cli(config-mst)#
Syntax
Call the command without parameters:
no revision
Result
The revision number of the MST region is reset to the default value.
Further notes
You assign a revision number to the MST region with the revision command.
You display this setting and other information with the
show spanning tree mst
configuration
command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals