Network protocols
7.3 DHCP server
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
310 Configuration Manual, 10/2015, C79000-G8976-C351-05
7.3.2.5
ip dhcp-server pool
Note
The command is only avail
able with the following device:
•
SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
•
SCALANCE W761-1 RJ45 in access point mode (article number): 6GK5761-1FC00-
0AA0
and 6GK5761-1FC00-0AB0 (US version))
Description
With this command, you have three options of changing to the DHCPPOOL configuration
mode and to assign an interface to the IPv4 address band.
1. If you call the
ip dhcp-server pool command without parameters, and IPv4 address band
with the next free pool ID is created and you change directly to the corresponding
DHCPPOOL configuration mode.
You then configure the interface and the other settings in the DHCPPOOL configuration
mode.
2. If you call the command
ip dhcp-server pool with the parameter pool-id (1-5), you
change to the corresponding DHCPPOOL configuration mode.
3. If you call the command
ip dhcp-server pool with the parameter show-interface-options,
you call a variant of the command. With this variant, you assign an interface to the IPv4
address band and change to the DHCPPOOL configuration mode. If the ID of the
address IPv4 address band does not yet exist, it will be created. You then configure the
other settings in the DHCPPOOL configuration mode.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ip dhcp-server pool { <pool-id (1-5)> | show-interface-options }
The parameters have the following meaning:
Parameter
Description
Range of values / note
pool-id
ID of the addressed IPv4
address band
1 ... 5
Only ID = 1 is supported.
show-interface-options
Displays the possible
options for the interface.
-
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals