EasyManua.ls Logo

Siemens SIMATIC NET

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
160 Configuration Manual, 10/2015, C79000-G8976-C351-05
6.1.5.5
wlan ampdu
Description
With this command, you enable the sending of AMPDU data packets. The function is
enabled as default.
Requirement
The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
wlan ampdu
Result
The sending of AMPDU data packets is enabled.
Further notes
You display the setting with the show wlan advanced-11n <wlan 0/X> command.
You disable the function with the
no wlan ampdu command.
See also
no wlan ampdu (Page 161)

Table of Contents

Other manuals for Siemens SIMATIC NET

Related product manuals