Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
216 Configuration Manual, 10/2015, C79000-G8976-C351-05
6.1.7.4
wds connection over (access point)
Description
With this command, you specify the VAP interface via which the WDS connection is
established.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode for the WDS interface.
The command prompt is as follows:
cli (config-if-wdsX-0-Y)#
Syntax
Call up the command with the following parameters:
wds conncection over <vapX 0/Y>
The parameter has the following meaning:
Parameter
Description
Range of values / note
wdsX 0/Y
Interface
Enter a valid interface.
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The VAP interface is set.
Further notes
You display the setting with the show wlan wds <wdsX 0/Y> command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals