System time
5.3 SNTP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
126 Configuration Manual, 10/2015, C79000-G8976-C351-05
Syntax
Call the command without parameters:
sntp
Result
You are now in the SNTP configuration mode.
The command prompt is as follows:
cli(config-sntp)#
Further notes
You exit the SNTP configuration modewith the end or exit command.
5.3.3
Commands in the SNTP configuration mode
This section describes commands that you can call up in the SNTP configuration mode.
In the Global configuration mode, enter the
sntp command to change to this mode.
If you exit the SNTP configuration mode with the
exit command, you return to the Global
configuration mode.
If you exit the SNTP configuration mode with the
end command, you return to the
Privileged EXEC mode.