EasyManua.ls Logo

Siemens SIMATIC NET

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostics
11.1 Diagnostics
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
450 Configuration Manual, 10/2015, C79000-G8976-C351-05
Syntax
Call up the command with the following parameters:
no link {up|down}
The parameters have the following meaning:
Parameters
Description
Range of values / note
up
The message when establishing a connection is
disabled
-
down
The message when a connection is down is disa-
bled
-
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You can display the current setting with the show events faults config command.
You enable the function with the
link command.
11.1.6.8
send test mail
Description
With this command, you send an e-mail according to the currently configured SMTP settings.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
send test mail
Result
An e-mail according to the currently configured SMTP settings is sent.
Further notes
You can display the current SMTP settings with the show events smtp-server command.