Network protocols
7.1 IPv4 protocol
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
291
7.1.2.8
no dcp server
Description
With this command, you disable the DCP server.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no dcp server
Result
The DCP server is disabled.
Further notes
You enable and configure the DCP server with the dcp server command.
7.1.2.9
ip domain lookup
Description
This command enables the DNS client of the device. To be able to use the function, a DNS
server must be reachable.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
ip domain lookup