Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
339
7.4.2.9
no snmp filterprofile
Description
With this command, you delete a filter.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp filterprofile<profile-name><OIDTree>
The parameters have the following meaning:
Parameters
Description
Range of values / note
profile-name
Name of the filter profile
max. 32 characters
OIDTree
Object ID
Path information of the MIB tree
Result
The filter is deleted.
Further notes
You create a filter with the snmp filterprofile command.
You display the created filter with the
show snmp filter table command.
7.4.2.10
snmp group
Description
With this command, you configure the details of an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals