Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
137
Syntax
Call up the command with the following parameters:
show wlan basic <wlan 0/X>
The parameter has the following meaning:
Parameter
Description
Range of values / note
wlan 0/X
WLAN interface
Enter a valid interface.
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The following WLAN settings are displayed:
Admin status (whether the interface is switched on or off)
Frequency band
WLAN mode
DFS (802.11h)
Outdoor Mode
Max Tx Power
TX power check: Indicates whether the current WLAN settings of the selected country
violate the permitted transmit power restrictions.
6.1.1.8
show wlan client (Client)
Description
This command shows the client configuration of the SCALANCE W700 device, for example
how the MAC address is assigned to the client.
Note
This command is only available in the client mode.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals