Diagnostics
11.1 Diagnostics
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
445
11.1.6.4
event config
Description
With this command, you configure which of the various message types of the device will be
stored or forwarded.
The following events or message types are available:
Message if there is cold or warm restart
Message when there is a status change on a physical interface
Message if there is an incorrect login
Message when there is a status change in the power supply
Message when there is a status change in the error monitoring
Message when there is a change in the spanning tree
Message if radio channels overlap
Message when changes are made to the connection status of WDS
Message if a radar signal is received or if there is a status change in the DFS scan.
Message if the channel bandwidth changes
Message for successful or failed authentication attempts
Message if there is a change in the error status (error LED)
Message when using iPCF.
These messages can be processed by the clients in different ways:
Entry in the logbook of the device
Sending the message to the log server of the system
Sending an e-mail
Sending an SNMP trap
Lighting up of the error LED
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals