Functions specific to SCALANCE
4.3 iPCF
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
102 Configuration Manual, 10/2015, C79000-G8976-C351-05
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameters:
wlan ipcf
Result
The iPCF mode is enabled.
Further notes
You disable the iPCF mode with the no wlan ipcf command.
You display the setting with the
show wlan ipcf command.
4.3.2.2
no wlan ipcf
Note
The command is only available with the following device:
•
SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
Description
With this command, you disable the iPCF mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameters:
no wlan ipcf
Result
The iPCF mode is disabled.
Further notes
You enable the iPCF mode with the wlan ipcf command.
You display the setting with the
show wlan ipcf command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals