Network protocols
7.3 DHCP server
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
306 Configuration Manual, 10/2015, C79000-G8976-C351-05
7.3.2.1
ip dhcp-server
Note
The command is only available with the following device:
SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
SCALANCE W761-1 RJ45 in access point mode (article number): 6GK5761-1FC00-
0AA0
and 6GK5761-1FC00-0AB0 (US version))
Description
With this command, you enable the DHCP server on the device.
Note
To avoid conflicts with IPv4 addresses, only one device may be configured as a DHCP
server in the network.
Note
Maximum number of IP addresses
The maximum number of IPv4 addresses that the DHCP server supports is 100. In other
words
, a total of 100 IPv4 addresses (dynamic + static).
With the static assignments, you can create a maximum of 20 entries.
Requirement
NAT is enabled in Client mode
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
ip dhcp-server
Result
The DHCP server is enabled.
Further notes
You disable the DHCP server with the no ip dhcp-server. command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals