Diagnostics
11.1 Diagnostics
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
436 Configuration Manual, 10/2015, C79000-G8976-C351-05
11.1.1.4
show events faults config
Description
This command shows the current configuration of the following error monitoring functions:
Monitoring of the power supply for power outage
Monitoring of the network connections for a change in the connection status
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
show events faults config [{link}]
The parameters have the following meaning:
Parameter
Description
link
Monitoring of the network connections for a change in the connection
status.
If no parameters are specified, the settings for error monitoring are displayed.
Result
The current configuration of the selected error monitoring function is displayed.
11.1.1.5
show events faults status
Description
This command shows the status messages of fault monitoring of the power supply and
network connections.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals