Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
271
6.3.4.7
spanning-tree bpdu-transmit
Description
With this command, you enable or disable the BPDU transmit status at the port.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
spanning-tree bpdu-transmit{enabled|disabled}
The parameters have the following meaning:
Parameter
Description
Range of values / note
enabled
BPDU packets are transmitted at the
port
Default: enabled
disabled
BPDU packets are not transmitted at
the port
-
Result
The BPDU transmit status has switched over.
Further notes
You can display the status of this function and other information with the show spanning-tree
interface
command with the detail option.
6.3.4.8
spanning-tree mst
Description
With this command, you configure the various properties of the Multiple Spanning Tree
function:
With the
cost option, you configure the port costs used to calculate the lowest-cost path.
With the
port-priority option, you configure the priority of the interface for negotiating a
Multiple Spanning Tree configuration.
With the
disable option, you disable the interface for the Multiple Spanning Tree function.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals