Network structures
6.3 Spanning Tree
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
249
6.3.2
clear spanning-tree counters
Description
With this command, you reset all the statistical counters of the spanning tree function at the
device and port level.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
clear spanning-tree counters
Result
The spanning tree counters are reset.
6.3.3
Commands in the global configuration mode
Requirements for changing to this mode:
MSTP is enabled
Base bridge mode: 802.1Q VLAN Bridge
Compatibility mode: MSTP
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end or exit command and are then in the
Privileged EXEC mode again.
6.3.3.1
spanning-tree
Description
The Spanning Tree Protocol is used to monitor a LAN for redundant connections. These are
blocked and reactivated when necessary if there are changes to the network topology.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals