Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
196 Configuration Manual, 10/2015, C79000-G8976-C351-05
6.1.5.45
wlan frequency band (client)
Description
With this command, you specify the frequency band for the WLAN interface.
Note
This command is only available in the client mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan frequency band { all | 2.4 | 5 }
The parameters have the following meaning:
Parameters
Description
Range of values / note
all
Both frequency bands are used.
Default settings: WLAN1: 2.4 GHz
2.4
Frequency band 2.4 GHz
5
Frequency band 5.2 (4.9; 5.6; 5.8) GHz
Result
The frequency band for the WLAN interface is specified.
Further notes
You display the setting with the show wlan basic <wlan 0/X> command.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals