Network protocols
7.1 IPv4 protocol
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
294 Configuration Manual, 10/2015, C79000-G8976-C351-05
7.1.2.13
ip domain used server
Description
This command specifies which DNS server the device uses.
Note
Only resource
records of type A (IPv4 address of a host) are supported.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ip domain used server {learned-only | manually-only | all}
The parameters have the following meaning:
Parameter
Description
Range of values / note
learned-only
The device uses only the DNS servers
assigned by DHCP.
-
manually-only
The device uses only the manually con-
figured DNS servers. A maximum of
three DNS servers can be configured.
-
all
The device uses all available DNS serv-
ers.
-
Result
The device uses the DNS servers specified in the configuration.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals