EasyManua.ls Logo

Siemens SIMATIC NET

Siemens SIMATIC NET
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network protocols
7.2 DHCP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
300 Configuration Manual, 10/2015, C79000-G8976-C351-05
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show ip dhcp client
Result
The configuration settings of the DHCP client are displayed.
7.2.2
renew dhcp
Description
This command reassigns an IP address to the selected interface via DHCP.
Requirement
The IP address of the selected interface was assigned via DHCP.
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameters:
renew dhcp [{vlan<vlan-id(1-4094)>|<interface-type><interface-id>}]
The parameters have the following meaning:
Parameter
Description
Range of values / note
vlan
Keyword for a VLAN connection
-
vlan-id
Number of the addressed VLAN 1 ... 4094
interface-
type
Type or speed of the interface Enter a valid interface.
interface-id
Module no. and port no. of the interface
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".

Table of Contents

Other manuals for Siemens SIMATIC NET

Related product manuals