Configuration
3.2 Load and Save
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
78 Configuration Manual, 10/2015, C79000-G8976-C351-05
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
tftp server {ipv4 <ucast-addr> | fqdn-name <FQDN>} [port<tcp port(1-65535)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IPv4 address
-
ucast-addr
Value for an IPv4 unicast address Enter a valid IPv4 unicast ad-
dress.
fqdn-name
Keyword for a domain name
-
FQDN
Domain name (Fully Qualified Domain
Name)
Maximum 100 characters
port
Keyword for the port of the server via
which the TFTP connection runs
-
tcp port
Number of the port
1 … 65535
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 25)".
Result
The settings for the access to the selected TFTP server are configured.
3.2.5.6
password
Description
With this command, you activate and configure the password for encrypted certificates.
User, server or HTTPS certificates can exist as PKCS#12 certificates (.p12 and .pfx) and
PEM certificates (.pem).
Note
User and server certificate in one file
If the user and the server certificate are loc
ated in the same file, load this file on the device
as the user certificate and as the server certificate.
Requirement
You are in the LOADSAVE configuration mode.
The command prompt is as follows:
cli(config-loadsave)#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals