Security and authentication
10.2 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
423
10.2.5.6
vap security wpa-group-key-update-interval (Access Point)
Description
With this command you specify the time after which the key is renewed.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call up the command with the following parameters:
vap security wpa-group-key-update-interval {0|seconds (30-36000)}
The parameter has the following meaning:
Parameter
Description
Range of values / note
0
The key will not be renewed.
-
seconds
When the time expires (second),
the key is renewed.
30 ... 36000
Result
The time for renewal of the key is specified.

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals