System time
5.3 SNTP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
125
5.3.1.3
show sntp unicast-mode status
Description
This command shows the current configuration of the unicast mode of SNTP.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show sntp unicast-mode status
Result
The current SNTP unicast configuration is displayed.
5.3.2
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end or exit command and are then in the
Privileged EXEC mode again.
5.3.2.1
sntp
Description
With this command, you change to the SNTP configuration mode.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SIMATIC NET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET and is the answer not in the manual?

Siemens SIMATIC NET Specifications

General IconGeneral
CategoryIndustrial Communication Software
ManufacturerSiemens
Operating SystemsWindows, Linux
Protocols SupportedPROFIBUS, PROFINET, OPC UA
CompatibilitySiemens PLCs, Third-party devices with supported protocols

Related product manuals