5.2 NTP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
121
5.2.3.1
ntp server
Description
With this command, you configure the connection to a server on the NTP client.
Requirement
You are in the NTP configuration mode.
The command prompt is as follows:
cli(config-ntp)#
Syntax
Call up the command with the following parameters:
ntp server{ipv4 <ip_addr> | fqdn-name <FQDN>}[port<123,1025-36564>][poll<seconds(64-
1024)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IPv4 address
-
ip_addr
Value for the IPv4 address of the time
server
Enter a valid IPv4 address.
fqdn-name
Keyword for a domain name
-
FQDN
Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
port
UDP port of the time server
123
1025 … 36564
Default: 123
poll
Keyword for the time after which the
time of day is requested again
-
seconds
Value for the time in seconds
64 … 1024
For information on identifiers of addresses and interfaces, refer to the section "Addresses
and interface identifiers (Page 25)".
Result
The connection to a server is configured on the NTP client.
Further notes
You delete the connection to a server with the no ntp server command.